POWER REGULATION : Pitch regulated with variable speed
OPERATING DATA
Rated power: 3,450 kW
Cut-in wind speed : 3m/s
Cut-out wind speed : 25m/s
Re cut-in wind speed: 23m/s
Wind class: IEC IB/IEC IIA
Standard operating temperature range from: -20°C* to +45°C
with de-rating above: 30°C
*subject to different temperature options
SOUND POWER
Maximum 106.8dB(A)**
**Sound Optimised Modes dependent on site and country
ROTOR
Rotor diameter :117m
Swept area: 10,751m2
Air brake: full blade feathering with 3 pitch cylinders
ELECTRICAL
Frequency: 50/60Hz
Converter : full scale
GEARBOX
Type : two planetary stages and one helical stage
TOWER
Hub heights : 80m (IEC IB), 91.5m (IEC IB) and 116.5m (IEC IB/IEC IIA/DIBtS)
NACELLE DIMENSIONS
Height for transport : 3.4m
Height installed (incl. CoolerTop®): 6.9m
Length : 12.8m
Width: 4.2m
HUB DIMENSIONS
Max. transport height : 3.8m
Max. transport width: 3.8m
Max. transport length: 5.5m
BLADE DIMENSIONS
Length: 57.2m
Max. chord: 4.0m
Max. weight per unit for transportation: 70 metric tonnes
TURBINE OPTIONS
・ High Wind Operation
・ Power Optimised Mode up to 3.6 MW (site specific)
・ Load Optimised Modes down to 3.0 MW
・ Condition Monitoring System
・ Service Personnel Lift
・Ice Detection
・De-Icing
・ Low Temperature Operation to - 30°C
・ Fire Suppression
・ Shadow detection
・ Increased Cut-In
・ Aviation Lights
・ Aviation Markings on the Blades
Date | Manufacturer | Model | Quantity | Budget | Country |
---|---|---|---|---|---|
02/02/2023 | Enercon | E40/500 | 3 | Türkei | |
02/02/2023 | Enercon | E66/18.70 | 5 | Türkei | |
02/02/2023 | Enercon | E82/3000 | 1 | Litauen | |
01/02/2023 | Enercon | E-82 E4 | 1 | Irland | |
31/01/2023 | Enercon | E82/2300 | 2 | Frankreich | |
30/01/2023 | Enercon | E40/500 | 1 | Italien | |
30/01/2023 | Enercon | E18/80 | 1 | Deutschland | |
27/01/2023 | Enercon | E66/2000 | 1 | Italien |